This part of EN 14511 specifies the test methods for the rating and performance of air and water-cooled air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with electrically driven compressors when used for space heating and cooling. It also specifies the method of testing and reporting for heat recovery capacities, system reduced capacities and the capacity of individual indoor units of multisplit systems, where applicable. This European Standard applies to factory-made units that can be ducted. This standard applies to factory-made liquid chilling packages with integral condensers or for use with remote condensers. This standard applies to factory-made units of either fixed capacity or variable capacity by any means. Packaged units, single split and multisplit systems are covered by this standard. Single duct and double duct units are covered by the standard. In the case of units consisting of several parts, the standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser. This standard is primarily intended for water and brine chilling packages but can be used for other liquid subject to agreement. This standard applies to air-to-air air conditioners which evaporate the condensate on the condenser side. The units having their condenser cooled by air and by the evaporation of external additional water are not covered by this standard. This standard does not apply to units using transcritical cycles, e. g. with CO2 as refrigerant. Installations used for heating and/or cooling of industrial processes are not within the scope of this standard. NOTE 1 Part load testing of units is dealt with in CEN/TS 14825. NOTE 2 All the symbols given in this text should be used regardless of the language used.
Số hiệu tiêu chuẩn
EN 14511-3
Tên tiêu chuẩn
Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 3: Test methods
Ngày phát hành
2007-11-00
Tiêu chuẩn tương đương
DIN EN 14511-3 (2008-02), IDT * BS EN 14511-3 (2007-12-31), IDT * NF E38-116-3 (2008-01-01), IDT * SN EN 14511-3 (2008-02), IDT * OENORM EN 14511-3 (2008-03-01), IDT * OENORM EN 14511-3 (2008-12-01), IDT * OENORM EN 14511-3 (2007-06-01), IDT * PN-EN 14511-3 (2008-02-11), IDT * SS-EN 14511-3 (2007-12-06), IDT * UNE-EN 14511-3 (2008-05-28), IDT * UNI EN 14511-3:2008 (2008-07-10), IDT * STN EN 14511-3 (2008-05-01), IDT * CSN EN 14511-3 (2008-06-01), IDT * DS/EN 14511-3 (2008-02-22), IDT * NEN-EN 14511-3:2007 en (2007-12-01), IDT * SANS 54511-3:2010 (2010-04-29), IDT * SFS-EN 14511-3:en (2008-07-18), IDT
Từ khóa
Air * Air conditioner * Air conditioners * Air conditioning * Air coolers * Air exchange * Air-conditioning equipment * Air-conditioning systems * Air-cooled * Air-cooled systems * Air-to-air heat exchangers * Checking equipment * Compactors * Compressors * Conditioning * Cooling * Cooling capacity * Designations * Efficiency * Electric motors * Electrical * Electrical transmission systems * Electrically-operated devices * Features * Heat * Heat engineering * Heat output * Heat pumps * Heat transfer media * Heating * Heating equipment * Inserts * Installation * Installations * Marking * Measurement * Noise * Noise emission * Noise (environmental) * Operative ranges * Parameters * Performance * Performance testing * Power consumption * Power measurement (electric) * Power ratings * Properties * Pumps * Rated power * Rating tests * Ready for connnection * Refrigeration * Room air conditioners * Room air conditioning equipment * Sound * Space-heating systems * Specification (approval) * Start * Starting tests * Temperature * Terminology * Terms * Test reports * Test temperatures * Testing * Testing conditions * Testing requirements * Type of unit * Types * Unit coolers * Vocabulary * Waste heat recovery * Water cooling * Water-cooled * Wear-quantity * Power measurement * Mission * Use * Testing devices