IEC/TS 60695-2-20*CEI/TS 60695-2-20

Fire hazard testing - Part 2-20: Glowing/hot wire based test methods - Hot-wire coil ignitability - Apparatus, test method and guidance

Số trang: 44
Ngày phát hành: 2004-02-00

Liên hệ
Applicable to solid electrical insulating materials. It is intended to measure the time required to ignite the test specimen during the application of heat from an electrically heated coil as an ignition source. This test method is not valid for determining the ignition behaviour of complete items of equipment, since the dimensions of the insulating systems or combustible parts, the design and heat transfer to adjacent metallic or non-metallic parts, etc. greatly influence the ignitability of the electrical insulating materials used therein. In addition, it is not valid for determining fire behaviour and fire hazard of equipment. The data may be used for the preselection of a material as described in IEC 60695-1-30. The optional Performance Level Category (PLC) system described in Annex B is intended for the preselection of component materials for products. An alternative test for ignitability is IEC 60695-2-13. However, no correlation has been established between IEC 60695-2-20 and IEC 60695-2-13. The status of this publication has been reassigned from an International Standard to a Technical Specification, however, the structure and layout remains essentially the same. Every technical aspect of this test method has been reviewed in an attempt to improve both the repeatability and reproducibility. Annex A has been added for the determination of the test current Ic. Annex B has been added which introduces the concept of a Performance Level Category (PLC). Has the status of a basic safety publication in accordance with IEC Guide 104
Số hiệu tiêu chuẩn
IEC/TS 60695-2-20*CEI/TS 60695-2-20
Tên tiêu chuẩn
Fire hazard testing - Part 2-20: Glowing/hot wire based test methods - Hot-wire coil ignitability - Apparatus, test method and guidance
Ngày phát hành
2004-02-00
Trạng thái
Hết hiệu lực
Tiêu chuẩn tương đương
BS DD IEC TS 60695-2-20 (2004-05-21), IDT * GOST R 54019 (2010), IDT * NPR-IEC/TS 60695-2-20:2004 en;fr (2004-03-01), IDT
Tiêu chuẩn liên quan
IEC Guide 104 (1997-08) * IEC 60695-1-30 (2002-06) * ISO 291 (1997-08) * ISO 293 (1986-10) * ISO 294 Reihe * ISO 295 (1991-11) * ISO 295 (2004-02) * ISO/IEC 13943 (2000)
Thay thế cho
IEC 60695-2-20*CEI 60695-2-20 (1995-08)
Fire hazard testing - Part 2: Glowing/hot wire based test methods - Section 20: Hot-wire coil ignitability test on materials
Số hiệu tiêu chuẩn IEC 60695-2-20*CEI 60695-2-20
Ngày phát hành 1995-08-00
Mục phân loại 13.220.40. Tính dễ bắt lửa và dễ cháy của vật liệu và sản phẩm
29.035.01. Vật liệu cách điện nói chung
Trạng thái Có hiệu lực
Thay thế bằng
Lịch sử ban hành
IEC/TS 60695-2-20*CEI/TS 60695-2-20 (2004-02)
Fire hazard testing - Part 2-20: Glowing/hot wire based test methods - Hot-wire coil ignitability - Apparatus, test method and guidance
Số hiệu tiêu chuẩn IEC/TS 60695-2-20*CEI/TS 60695-2-20
Ngày phát hành 2004-02-00
Mục phân loại 13.220.40. Tính dễ bắt lửa và dễ cháy của vật liệu và sản phẩm
29.035.01. Vật liệu cách điện nói chung
Trạng thái Có hiệu lực
* IEC 60695-2-20*CEI 60695-2-20 (1995-08)
Fire hazard testing - Part 2: Glowing/hot wire based test methods - Section 20: Hot-wire coil ignitability test on materials
Số hiệu tiêu chuẩn IEC 60695-2-20*CEI 60695-2-20
Ngày phát hành 1995-08-00
Mục phân loại 13.220.40. Tính dễ bắt lửa và dễ cháy của vật liệu và sản phẩm
29.035.01. Vật liệu cách điện nói chung
Trạng thái Có hiệu lực
Từ khóa
Definitions * Electric appliances * Electrical engineering * Electrotechnical products * Fire hazard test * Fire risks * Hot-wires * Ignitability * Testing
Số trang