Loading data. Please wait

IEC 61300-2-19*CEI 61300-2-19

Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-19: Tests - Damp heat (steady state)

Số trang: 9
Ngày phát hành: 1995-06-00

Liên hệ
Determines the suitability of a fibre optic device to withstand the environmental condition of high humidity and high temperature which may occur in actual use, storage and/or transport. Primarily intended to permit the observation of effects of high humidity at constant temperature over a given period. Absorption of moisture may result in swelling that would destroy functional utility, cause loss of physical strength, and cause changes in other important mechanical properties. Degradation of optical properties may also occur. This procedure is conducted in accordance with IEC 68-2-3, test Ca.
Số hiệu tiêu chuẩn
IEC 61300-2-19*CEI 61300-2-19
Tên tiêu chuẩn
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-19: Tests - Damp heat (steady state)
Ngày phát hành
1995-06-00
Trạng thái
Hết hiệu lực
Tiêu chuẩn tương đương
NF C93-902-19*NF EN 61300-2-19 (1997-12-01), IDT
Fibre optic interconnecting devices and passive components. Basic test and measurement procedures. Part 2-19 : tests. Damp heat (steady state).
Số hiệu tiêu chuẩn NF C93-902-19*NF EN 61300-2-19
Ngày phát hành 1997-12-01
Mục phân loại 33.180.20. Thiết bị sợi quang nối liền nhau
Trạng thái Có hiệu lực
* DIN EN 61300-2-19 (1998-09), IDT * BS EN 61300-2-19 (1997-10-15), IDT * GB/T 18310.19 (2002), IDT * EN 61300-2-19 (1997-08), IDT * prEN 61300-2-19 (1996-10), IDT * JIS C 5901 (2001-03-20), MOD * JIS C 5961 (1997-12-20), MOD * OEVE EN 61300-2-19 (1997-10-09), IDT * PN-EN 61300-2-19 (2002-10-18), IDT * SS-EN 61300-2-19 (1998-09-25), IDT * UNE-EN 61300-2-19 (1998-08-11), IDT * TS EN 61300-2-19 (2003-04-26), IDT * STN EN 61300-2-19 (2001-06-01), IDT * CSN EN 61300-2-19 (1998-11-01), IDT * NEN-EN-IEC 61300-2-19:1997 en (1997-09-01), IDT * NEN 11300-2-19:1995 en;fr (1995-08-01), IDT
Tiêu chuẩn liên quan
IEC 60068-2-3*CEI 60068-2-3 (1969)
Basic environmental testing procedures. Part 2 : Tests. Test Ca: Damp heat, steady state
Số hiệu tiêu chuẩn IEC 60068-2-3*CEI 60068-2-3
Ngày phát hành 1969-00-00
Mục phân loại 19.040. Thử môi trường
Trạng thái Có hiệu lực
Thay thế cho
IEC 86B/546/DIS (1994-12)
Thay thế bằng
IEC 61300-2-19*CEI 61300-2-19 (2005-03)
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-19: Tests - Damp heat (steady state)
Số hiệu tiêu chuẩn IEC 61300-2-19*CEI 61300-2-19
Ngày phát hành 2005-03-00
Mục phân loại 33.180.20. Thiết bị sợi quang nối liền nhau
Trạng thái Có hiệu lực
Lịch sử ban hành
IEC 61300-2-19*CEI 61300-2-19 (2005-03)
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-19: Tests - Damp heat (steady state)
Số hiệu tiêu chuẩn IEC 61300-2-19*CEI 61300-2-19
Ngày phát hành 2005-03-00
Mục phân loại 33.180.20. Thiết bị sợi quang nối liền nhau
Trạng thái Có hiệu lực
* IEC 61300-2-19*CEI 61300-2-19 (1995-06)
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-19: Tests - Damp heat (steady state)
Số hiệu tiêu chuẩn IEC 61300-2-19*CEI 61300-2-19
Ngày phát hành 1995-06-00
Mục phân loại 33.180.20. Thiết bị sợi quang nối liền nhau
Trạng thái Có hiệu lực
* IEC 61300-2-19*CEI 61300-2-19 (2012-11)
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-19: Tests - Damp heat (steady state)
Số hiệu tiêu chuẩn IEC 61300-2-19*CEI 61300-2-19
Ngày phát hành 2012-11-00
Mục phân loại 33.180.20. Thiết bị sợi quang nối liền nhau
Trạng thái Có hiệu lực
* IEC 86B/546/DIS (1994-12)
Từ khóa
Damp-heat tests * Fibre optics * Glass fibre cables * Measuring techniques * Optical waveguides * Testing
Số trang
9