Applies to track systems with two or more poles and with provision for earthing (Class I), with a rated voltage not exceeding 440 V between poles (live conductors), rated frequency not exceeding 60 Hz and a rated current not exceeding 16 A per conductor for the connection of luminaires to the electrical supply. Applies also to track systems designed for ordinary interior use for mounting on, or flush with, or suspended from walls and ceilings.
Số hiệu tiêu chuẩn
IEC 60570*CEI 60570
Tên tiêu chuẩn
Electrical supply track systems for luminaires
Ngày phát hành
1985-00-00
Tiêu chuẩn tương đương
NF C71-112*NF EN 60570 (1992-07-01), IDT * DIN EN 60570 (1995-07), MOD * DIN IEC 60570 (1979-03), IDT * DIN IEC 60570-100 (1979-12), IDT * 93/205328 DC (1993-04-19), IDT * BS 4533 Section 102.57 (1990-09-28), MOD * BS 4533-102-102.57 (1990-09-28), NEQ * BS EN 60570 (1994-02-15), MOD * EN 60570 (1993-08), MOD * prEN 60570 (1992-08), MOD * NF C71-112 (1985-09-01), IDT * NF C71-112 (1994-03-01), MOD * JIS C 8366 (1995-01-01), MOD * OEVE EN 60570 (1990-09-06), MOD * OEVE EN 60570 (1993-08-23), MOD * SS 4311170 (1989-09-13), IDT * UNE 20437 (1983-05-15), IDT * UNE-EN 60570 (1993-12-29), IDT * UNE-EN 60570 (1996-07-22), IDT * GOST IEC 60570 (2012), IDT * GOST R 50527 (1993), IDT * TS 10077 (1992-03-31), IDT * NBN C 71-570 (1988), IDT * NEN 10570, MOD * NP 3520 (1987), IDT * STN EN 60570 (1997-05-01), MOD * NEN 10570:1994 en;fr (1994-02-01), MOD
Từ khóa
Conductor rails * Definitions * Dimensions * Earth conductors * Electric current * Electric lamps * Electric power systems * Electric terminals * Electrical engineering * Electrical installations * Frequencies * General lighting service lamps * Hands (anatomy) * Lamps * Leakage paths * Lighting systems * Luminaires * Rated current * Rated voltage * Safety engineering * Screws (bolts) * Specification (approval) * Strength of materials * Systems * Temperature * Test equipment * Test fingers * Thermal stability * Torque * Working stress * Dielectric strength * Insulating resistance * Protective insulations * Clearances * Electric conductors * Bending moment * Mounting materials * Testing requirements * Pressure tests * Cross sections * Adapters * Classes of protection * Specimens * Currents * High * Supply track systems * Testing * Combination * Design * Measuring pins * Bend testing * Bodies * Base insulation * Test apparatus * Strain relief * Active * Electric mains * Easy-reach area * Connectors * Striking energy * Flexible * Working voltage * Insulating materials * Operating insulation * Rails * Pipelines * VDE specifications * Insulations * Spring hammers * Earthing conductor terminations * Reinforced * Ball pressure test equipment * Electric cables * Stress * Cords * Screw terminals * Illumination engineering * Socket terminal strips * Voltage * Operating temperatures * Springs * Hot-mandrel * Inscription * Moisture resistance * Conductor cross section * Feathers * Contact safety devices * Conduits * Graphic symbols