Loading data. Please wait

prEN 60228

IEC 60228, Ed. 3: Conductors of insulated cables

Số trang:
Ngày phát hành: 2004-08-00

Liên hệ
This draft specifies the nominal cross-sectional areas, in the ränge 0,2 mm2 to 2500 mm2, for conductors in electric power cables and cords of a wide range of types. Requirements for numbers and sizes of wires and resistance values are also included. These conductors include solid and stranded copper, aluminium and aluminium alloy conductors in cables for fixed installations and flexible copper conductors.
Số hiệu tiêu chuẩn
prEN 60228
Tên tiêu chuẩn
IEC 60228, Ed. 3: Conductors of insulated cables
Ngày phát hành
2004-08-00
Trạng thái
Hết hiệu lực
Tiêu chuẩn tương đương
IEC 20/718/FDIS (2004-08), IDT
Tiêu chuẩn liên quan
Thay thế cho
prEN 60228 (2003-05)
IEC 60228, Ed. 3.0: Conductors of insulated cables
Số hiệu tiêu chuẩn prEN 60228
Ngày phát hành 2003-05-00
Mục phân loại 29.060.20. Cáp
Trạng thái Có hiệu lực
Thay thế bằng
EN 60228 (2005-02)
Conductors of insulated cables (IEC 60228:2004)
Số hiệu tiêu chuẩn EN 60228
Ngày phát hành 2005-02-00
Mục phân loại 29.060.20. Cáp
Trạng thái Có hiệu lực
Lịch sử ban hành
EN 60228 (2005-02)
Conductors of insulated cables (IEC 60228:2004)
Số hiệu tiêu chuẩn EN 60228
Ngày phát hành 2005-02-00
Mục phân loại 29.060.20. Cáp
Trạng thái Có hiệu lực
* prEN 60228 (2004-08)
IEC 60228, Ed. 3: Conductors of insulated cables
Số hiệu tiêu chuẩn prEN 60228
Ngày phát hành 2004-08-00
Mục phân loại 29.060.20. Cáp
Trạng thái Có hiệu lực
* prEN 60228 (2003-05)
IEC 60228, Ed. 3.0: Conductors of insulated cables
Số hiệu tiêu chuẩn prEN 60228
Ngày phát hành 2003-05-00
Mục phân loại 29.060.20. Cáp
Trạng thái Có hiệu lực
Từ khóa
Acceptance inspection * Accessories * Alternating current * Alternating voltages * Aluminium * Aluminium wires * Bend testing * Cable plants * Cables * Coats * Conductive materials * Copper * Copper conductors * Copper wires * Core sheaths * Corrosion protection * Definitions * Dielectric materials * Dimensions * Direct current * Direct voltage * Dissipation factor * Electric cables * Electric conductors * Electric power transmission lines * Electrical cords * Electrical engineering * Electrical resistance * External gas-pressure cables * Flexible * Flexible cables * Gases * Guide books * Guidelines * High tension leads * High voltage * High-voltage techniques * Identification bands * Impulse voltages * Inspection * Installations for rated voltages * Insulated * Insulated cables * Insulating coverings * Insulations * Internal gas pressure cables * Lagging of a drum * Lead sheaths * Lead-sheathed cables * Length * Low pressure * Low-pressure cable * Manufacturing * Marking * Materials * Maximum values * Metal sheaths * Minimum * Multi-wire * Nominal cross section areas * Number of wires * Oil-filled electric cables * Paper * Paper insulation * Plastics * Plastics sheaths * Polyvinyl chloride * Power cables * Power current * Power installations * Power lines * Pressure overload * Protective coverings * Qualification tests * Rated voltage * Resistance measurement * Resistance of conductor * Round conductors * Routine check tests * Safety engineering * Sector conductors * Single wire * Steel tubes * Stranding * Symbols * Temperature * Tensile strength * Test specimens * Testing * Testing voltages * Three-phase current * Three-phase systems * Tolerances (measurement) * Wall thicknesses * Waveguides * Steel pipes
Mục phân loại
Số trang