This European Standard specifies the requirements and test methods for the design, manufacturing, safe operation and the rational energy usage for standard boilers and low temperature boilers (with ""boiler"" in the sense of ""boiler body"") from steel and cast iron to be equipped with separately marketed forced draught burners according to the relevant burner standards (for automatic forced draught burners for gaseous fuels see EN 676 and for atomising oil burners see EN 267) up to a nominal heat output of 10 MW. They are operated, either with negative pressure (natural draught boiler) or with positive pressure (pressurised boiler) in the combustion chamber, in accordance with the boiler manufacturer's instructions.""This European Standard specifies requirements for boilers with normal operating temperatures between 100 °C and 110 °C and has a ""dual structure"":- For boilers where the shut off temperature of the safety temperature limiter does not exceed 110 °C the Pressure Equipment Directive (PED) requires"" Sound Engineering Practice"", - For boilers where the shut off temperature of the safety temperature limiter exceeds 110 °C this European Standard specifies the requirements of the PED as stated in Annex ZB.NOTE 1 The ""maximum allowable temperature TS"" is defined in the PED and its Guidelines.""Boilers in accordance with this European Standard are designed for the heating of central heating installations in which the heat carrier is water, and the maximum allowable operating temperature of which is up to 110 ï,°C and the maximum safety temperature limiter of 120 ï,°C. The maximum allowable operating pressure is 10 bar.This standard does not apply to gas boilers with atmospheric burners, boilers for solid fuels, oil or gas fired condensation boilers, boilers with oil vaporisation burners. For these boilers there are further requirements.For gas-fired central heating boilers equipped with a forced draught burner of nominal heat out put ...
Số hiệu tiêu chuẩn
DS/EN 14394 + A1
Tên tiêu chuẩn
Heating boilers - Heating boilers with forced draught burners - Nominal heat output not exceeding 10 MW and maximum operating temperature of 110 °C
Ngày phát hành
2008-11-05
Tiêu chuẩn tương đương
IDTEN 14394:2005+A1:2008, IDT
Thay thế cho
DS/EN 14394:2006
Từ khóa
AIR-BLAST BURNERS * ATOMIZING BURNERS * ATOMIZING OIL BURNERS * BOILER EFFICIENCY * BOILERS * BURNERS * CENTRAL HEATING * DEFINITION * DEFINITIONS * DIMENSIONING * DIMENSIONS * HEATING TECHNICS * LIQUID FUEL APPLIANCES * MARKING * MATERIALS * OIL BURNERS * SPECIFICATION (APPROVAL) * TERMINOLOGY * TESTING * THERMAL PROPERTIES * THERMAL TEST * THERMAL TESTING * SPECIFICATIONS * Terminology * Thermal testing * Specifications * Specification (approval) * Cloth * Burners * Liquid fuel appliances * Marking * Thermal properties * Dimensioning * Heating technics * Fabrics * Materials * Thermal test * Atomizing oil burners * Boiler efficiency * Atomizing burners * Air-blast burners * Definitions * Central heating * Dimensions * Oil burners * Testing * Boilers * Substances