This document specifies definitions and requirements for cold applied non structural elastic sealants used for movement joints in floors in building construction for interior and exterior use. Areas of application are: floor joints which have been designed for pedestrian walkways, public areas, movement joints between concrete slabs, areas with pedestrian load, areas which are used with trolleys, walkable floors, balconies, terraces, warehouses. NOTE Provisions on evaluation of conformity (i.e. Initial Type Testing and Factory Production Control) and marking of these products are given in EN 15651-5. Chemical containment, cold applied joint sealants for concrete pavements to be used in roads, airfields and sewage treatment plants, perimeter seals are excluded.
Số hiệu tiêu chuẩn
FprEN 15651-4
Tên tiêu chuẩn
Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 4: Sealants for pedestrian walkways
Ngày phát hành
2009-10-00
Từ khóa
Building sealants * Buildings * Conformity * Construction * Construction materials * Definitions * Elastic * Exterior areas * Exterior circulation spaces (buildings) * Floors * Joint sealants * Joint sealings * Joints * Movement joints * Pedestrian crossings * Properties * Sealing * Sealing materials * Sealing means * Specification (approval) * Bottom * Ground * Soils