IEC 60332-1-3*CEI 60332-1-3

Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flaming droplets/particles

Số trang: 30
Ngày phát hành: 2004-07-00

Liên hệ
Specifies a test procedure for assessment of falling flaming droplets/ particles when a single vertical electrical insulated conductor or cable, or optical fibre cable, is subjected to defined fire conditions. NOTE - Testing to IEC 60332-1-3 may be performed simultaneously with that to IEC 60332-1-2, if required. Recommended requirements for performance are given in Annex A. IEC 60332-1-3 specifies the use of a 1 kW pre-mixed flame and is for general use, except that the procedure specified may not be suitable for the testing of small single insulated conductors or cables of less than 0,5 mm2 total cross-section because the conductor melts before the test is completed, or for the testing of small optical fibre cables because the cable is broken before the test is completed. Has the status of a group safety publication in accordance with IEC Guide 104.
Số hiệu tiêu chuẩn
IEC 60332-1-3*CEI 60332-1-3
Tên tiêu chuẩn
Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flaming droplets/particles
Ngày phát hành
2004-07-00
Trạng thái
Có hiệu lực
Tiêu chuẩn tương đương
DIN EN 60332-1-3 (2005-06), IDT * BS EN 60332-1-3 (2004-12-13), IDT * GB/T 18380.13 (2008), IDT * EN 60332-1-3 (2004-11), IDT * NF C32-078-1-3 (2005-03-01), IDT * JIS C 3665-1-3 (2007-07-20), IDT * OEVE/OENORM EN 60332-1-3 (2005-08-01), IDT * PN-EN 60332-1-3 (2005-04-15), IDT * PN-EN 60332-1-3 (2010-12-02), IDT * SS-EN 60332-1-3 (2004-12-20), IDT * UNE-EN 60332-1-3 (2005-04-20), IDT * GOST IEC 60332-1-3 (2011), IDT * GOST R IEC 60332-1-3 (2007), IDT * TS EN 60332-1-3 (2008-04-10), IDT * STN EN 60332-1-3 (2005-04-01), IDT * STN EN 60332-1-3 (2005-09-01), IDT * CSN EN 60332-1-3 (2005-04-01), IDT * DS/EN 60332-1-3 (2005-01-27), IDT * NEN-EN-IEC 60332-1-3:2005 en;fr (2005-02-01), IDT * SANS 60332-1-3:2005 (2005-04-13), IDT
Tiêu chuẩn liên quan
IEC 60332-1-1*CEI 60332-1-1 (2004-07)
Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulated wire or cable - Apparatus
Số hiệu tiêu chuẩn IEC 60332-1-1*CEI 60332-1-1
Ngày phát hành 2004-07-00
Mục phân loại 13.220.40. Tính dễ bắt lửa và dễ cháy của vật liệu và sản phẩm
29.060.20. Cáp
33.180.10. Sợi và cáp
Trạng thái Có hiệu lực
* IEC Guide 104 (1997-08) * ISO 187 (1990-12)
Thay thế cho
IEC 20/698/FDIS (2004-04)
Thay thế bằng
Lịch sử ban hành
IEC 60332-1-3*CEI 60332-1-3 (2004-07)
Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flaming droplets/particles
Số hiệu tiêu chuẩn IEC 60332-1-3*CEI 60332-1-3
Ngày phát hành 2004-07-00
Mục phân loại 13.220.40. Tính dễ bắt lửa và dễ cháy của vật liệu và sản phẩm
29.060.20. Cáp
33.180.10. Sợi và cáp
Trạng thái Có hiệu lực
* IEC 20/698/FDIS (2004-04) * IEC 20/638/CDV (2003-05)
Từ khóa
Burning behaviours * Cables * Definitions * Dimensions * Electric cables * Electric conductors * Electrical cords * Electrical engineering * Fibres * Fire resistance * Flame propagation * Flame resistance * Igniting sources * Insulated cables * Insulated cords * Insulated wires * Optical waveguides * Power cables * Single-core cables * Test equipment * Testing * Vertical
Số trang
30