Loading data. Please wait

SABS 1181-1:1978

Enamelled copper conductors Part 1: Round conductors with a polyvinyl acetal based enamel with high mechanical properties

Số trang: 44
Ngày phát hành: 1978-06-08

Liên hệ
Covers round copper conductors of nominal diameter 0,016-5,000 mm (inclusive), covered with a synthetic enamel having a polyvinyl acetal base with high mechanical properties. Requirements are given for the material, dimensions, thickness of covering (grade), and physical and electrical properties.
Số hiệu tiêu chuẩn
SABS 1181-1:1978
Tên tiêu chuẩn
Enamelled copper conductors Part 1: Round conductors with a polyvinyl acetal based enamel with high mechanical properties
Ngày phát hành
1978-06-08
Trạng thái
Hết hiệu lực
Tiêu chuẩn tương đương
Tiêu chuẩn liên quan
SABS 804
Thay thế cho
Thay thế bằng
Lịch sử ban hành
Từ khóa
ABRASION * ADHESION * BREAKDOWN VOLTAGE * CHEMICAL-RESISTANCE TESTS * COPPER * DIAMETER * DIMENSIONAL MEASUREMENT * DIMENSIONS * ELECTRIC CONDUCTORS * ELECTRIC WIRES * ELECTRICAL COMPONENTS * ELECTRICAL RESISTANCE * ELECTRICAL TESTING * ELONGATION * ENAMELLED WIRES * FLEXIBILITY * INSULATING COATINGS * MARKING * MECHANICAL TESTING * PACKAGING * PEELING TESTS * POLYVINYL ACETAL * RESILIENCE * SAMPLING METHODS * SCRATCH TESTS * SOLVENT-RESISTANCE TESTS * SPECIFICATIONS * THERMAL RESISTANCE * THERMAL-SHOCK RESISTANCE * THICKNESS * WEAR RESISTANCE * Dimensional measurement * Wear resistance * Electrical testing * Electric conductors * Diameter * Elongation * Electric wires * Polyvinyl acetal * Packaging * Copper * Chemical-resistance tests * Adhesion * Solvent-resistance tests * Resilience * Sclerometer tests * Scratch tests * Thermal resistance * Sampling methods * Expansions * Specifications * Thermal-shock resistance * Electrical components * Springiness * Marking * Dimensions * Breakdown voltage * Liability * Electrical resistance * Thickness * Enamelled wires * Flexibility * Abrasion * Peeling tests * Mechanical testing * Insulating coatings
Mục phân loại
Số trang
44